Don't have an account? Register today

Knowledge Base

Introducing MarvelX™ - A revolution in UHPLC connection systems

MarvelX UHPLC fittings

Kinesis has been awarded the status of Global Distributor for the IDEX Health & Science MarvelX™ range of UHPLC Connection products.

MarvelX UHPLC Connection Systems have been expertly designed for easy routing throughout your instrument, while providing consistent performance and superior re-usability. Built with a convenient, removable stainless steel fitting and changeable precision-cut flexible tubing, MarvelX is finger-tight to over 19,000psi and can be used up to 200 times.

MarvelX is compatible with 10-32 coned receiving ports and uses patented technology to automatically adjust to various port depths. This ensures zero dead volume and delivers better chromatography results with sleek, simple and reliable functionality.

In addition to the powerful Stainless Steel version, MarvelX offers a truly biocompatible option in PEEK-Lined Stainless Steel.

Global Distributor

MarvelX better, easier finger-tight connection systems

  • Finger-tight to 19,000 psi
  • Reusable up to 200 times
  • Zero Dead Volume
  • Biocompatible
  • No Peak Tailing
  • High Plate Efficiency
  • Robust Tip Minimizes Chance of Damage

Full Product Range - Ordering Details

To view the full MarvelX product range and place your order online, follow this link: ORDER NOW

  

MarvelX On-Demand Web Cast

Topic: Maximise your UHPLC capability by minimising extra volume in the system

WATCH NOW

 

MarvelX UHPLC fittings

MarvelX UHPLC fittings MarvelX UHPLC fittings do not depend on ferrules. They seal at the bottom of the port, without complex techniques, which significantly reduces required torque and enables many more connects and disconnects. Furthermore, they are virtually impossible to over-tighten by hand, limiting wear and increasing product life. An enhanced proprietary tip design also ensures zero dead volume (ZDV) and better chromatography results.

Conventional coned fittings

Conventional coned fittings Conventional coned fittings require a ferrule in conjunction with a fitting for proper sealing. They depend on complex techniques, including tools, to improve sealing performance, which significantly increases probability of extra internal volume and poor chromatography results. The excessive force needed for tightening increases wear of expensive components and the likelihood of replacement, adding to overall costs.

 

Eliminate Dead Volume in UHPLC with MarvelX

Dead volume in UHPLC is a major issue especially if the extra-column volume is so high it causes loss of efficiency and resolution. In UHPLC dead volume can be especially damaging due to the small extra column volumes encountered in a typical system. If critical connections are not made 100% efficiently any additional dead volume will drastically reduce the performance and resolution offered by UHPLC. Another feature of UHPLC is high throughput, therefore in gradient UHPLC it is important to have a small gradient delay, or dwell volume so connection volumes should be kept to a practical minimum from the pump to the injection valve.

The MarvelX fingertight connection system has been developed to offer the UHPLC user unparalleled performance and flexibility in making reliable, dead volume free connections.

The table below shows the volumes for each MarvelX connection kit to help you make the best selection for your application. 

MarvelX Tubing Volumes

0.08 MB

Date posted: 23rd May 2016 , 1:48pm

 

 

Further Information

If you have any questions about the IDEX Health & Science MarvelX™ range of UHPLC Connection products or would like us to identify an equivalent product from the MarvelX range to a product you already use, please fill in the details below and one of our team will be in touch.

    Thank you for your submission.

    Fill in the form below to request more information regarding this product.

    * Required Fields

    • By submitting your details you are indicating your consent to receiving further information via email from Kinesis.


    Product Brochure

    Click the thumbnail below to download the MarvelX brochure.

      MarvelX - Next Generation UHPLC Connection Technology

      3.15 MB

      Date posted: 26th Jan 2016 , 11:44am